Mfg Part Number: S4293 | NSN : 5950-00-867-5566 | NIIN : 008675566 |
CAGE Code : 80023 | Manufacturer: Vishay Intertechnology Inc | Item Name : Reactor Transformer |
FSC : 5950 Coils and Transformers |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 5950-00-867-5566 parts and components with Reactor Transformer manufactured by MFG Vishay Intertechnology Inc. Some of the items we carry include part number S4293, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 5950-00-867-5566 products S4293 that we feature by Vishay Intertechnology Inc are paired alongside their corresponding CAGE Code 80023 and FSC 5950 Coils and Transformers More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-867-5566 Item Description: Reactor Transformer | 5950 | 008675566 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
S4293 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 7.375 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 2.250 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 3.500 INCHES NOMINAL" |
ABTB | MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL 2ND GROUP" |
ACYV | INDUCTANCE RATING | 500.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE 2ND COMPONENT" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP" |
AKPV | MOUNTING FACILITY QUANTITY | 6 1ST GROUP" |
AXGY | MOUNTING METHOD | THREADED STUD ALL GROUPINGS OR UNTHREADED HOLE ALL GROUPINGS" |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES 1ST GROUP" |
CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.180 SINGLE COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 12.80 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 20.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY" |
FEAT | SPECIAL FEATURES | OUTPUT OF PHASE CONVERSION TRANSFORMER IS 6 PHASE STAR WINDING" |
THSD | THREAD SERIES DESIGNATOR | UNF 1ST GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 14 STANDOFF, SOLDER LUG" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 7.375 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 2.250 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 3.500 INCHES NOMINAL" |
ABTB | MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL 2ND GROUP" |
ACYV | INDUCTANCE RATING | 500.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE 2ND COMPONENT" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 2ND GROUP" |
AKPV | MOUNTING FACILITY QUANTITY | 6 1ST GROUP" |
AXGY | MOUNTING METHOD | THREADED STUD ALL GROUPINGS OR UNTHREADED HOLE ALL GROUPINGS" |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE SECONDARY" |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING" |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP" |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES 1ST GROUP" |
CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.180 SINGLE COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 12.80 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 20.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY" |
FEAT | SPECIAL FEATURES | OUTPUT OF PHASE CONVERSION TRANSFORMER IS 6 PHASE STAR WINDING" |
THSD | THREAD SERIES DESIGNATOR | UNF 1ST GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 14 STANDOFF, SOLDER LUG" |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote