Mfg Part Number: S5175 | NSN : 5950-00-832-9443 | NIIN : 008329443 |
CAGE Code : 80023 | Manufacturer: Vishay Intertechnology Inc | Item Name : Reactor Transformer |
FSC : 5950 Coils and Transformers |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 5950-00-832-9443 parts and components with Reactor Transformer manufactured by MFG Vishay Intertechnology Inc. Some of the items we carry include part number S5175, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 5950-00-832-9443 products S5175 that we feature by Vishay Intertechnology Inc are paired alongside their corresponding CAGE Code 80023 and FSC 5950 Coils and Transformers More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-832-9443 Item Description: Reactor Transformer | 5950 | 008329443 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
S5175 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKW | OVERALL HEIGHT | 3.000 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 3.260 INCHES NOMINAL" |
ACYV | INDUCTANCE RATING | 2.00 MILLIHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 0.0507 2ND COMPONENT" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP" |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING" |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 0.005 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.080 SINGLE COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET 2ND COMPONENT SINGLE SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR DRY 2ND COMPONENT SINGLE PRIMARY AND 208.00 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND COMPONENT SINGLE PRIMARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG AND 5 WIRE HOOK" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKW | OVERALL HEIGHT | 3.000 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 3.260 INCHES NOMINAL" |
ACYV | INDUCTANCE RATING | 2.00 MILLIHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZH | PRIMARY TO SECONDARY TURN RATIO | 1 TO 0.0507 2ND COMPONENT" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP" |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING" |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE PRIMARY" |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 0.005 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING" |
CRGS | DC RESISTANCE RATING IN OHMS | 0.080 SINGLE COMPONENT SINGLE WINDING" |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET 2ND COMPONENT SINGLE SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR DRY 2ND COMPONENT SINGLE PRIMARY AND 208.00 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND COMPONENT SINGLE PRIMARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG AND 5 WIRE HOOK" |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote