Mfg Part Number: GDB-1830 | Alternate P/N: GDB1830 | NSN : 5945-00-868-4413 |
NIIN : 008684413 | CAGE Code : 52401 | Manufacturer: Precision Switching Inc |
Item Name : Relay Electromagnetic | FSC : 5945 Relays and Solenoids |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 5945-00-868-4413 parts and components with Relay Electromagnetic manufactured by MFG Precision Switching Inc. Some of the items we carry include part number GDB-1830, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 5945-00-868-4413 products GDB-1830 that we feature by Precision Switching Inc are paired alongside their corresponding CAGE Code 52401 and FSC 5945 Relays and Solenoids More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-868-4413 Item Description: Relay Electromagnetic | 5945 | 008684413 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Gdb-1830 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.880 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 3.130 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 2.880 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.171 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
CBBL | FEATURES PROVIDED | POLARIZED" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION" |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 208.0 AC" |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 115.0 AMPERES AC RESISTIVE LOAD AND 28.0 AMPERES DC RESISTIVE LOAD" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ALL FUNCTIONS" |
ABHP | OVERALL LENGTH | 2.880 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 3.130 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 2.880 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.171 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AKDX | WINDING QUANTITY | 1" |
APCN | COIL QUANTITY | 1" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
CBBL | FEATURES PROVIDED | POLARIZED" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION" |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 208.0 AC" |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 115.0 AMPERES AC RESISTIVE LOAD AND 28.0 AMPERES DC RESISTIVE LOAD" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ALL FUNCTIONS" |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote