Mfg Part Number: 9216 | NSN : 5950-00-165-3694 | NIIN : 001653694 |
CAGE Code : 94315 | Manufacturer: New England Trawler Equipment Co | Item Name : Transformer Power |
FSC : 5950 Coils and Transformers |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 5950-00-165-3694 parts and components with Transformer Power manufactured by MFG New England Trawler Equipment Co. Some of the items we carry include part number 9216, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 5950-00-165-3694 products 9216 that we feature by New England Trawler Equipment Co are paired alongside their corresponding CAGE Code 94315 and FSC 5950 Coils and Transformers More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-165-3694 Item Description: Transformer Power | 5950 | 001653694 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9216 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.927 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.947 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABMK | OVERALL WIDTH | 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM" |
ABTD | MOUNTING SLOT WIDTH | 0.100 INCHES MINIMUM SINGLE GROUP AND 0.160 INCHES MAXIMUM SINGLE GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA" |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 446.5 VOLT-AMPERE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 1.280 INCHES MINIMUM AND 1.340 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | OPEN" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND SLOT SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 1.8 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 900.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CRMJ | WINDING POWER RATING | 238.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY" |
CRMJ | WINDING POWER RATING | 24.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY" |
CRMJ | WINDING POWER RATING | 45.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY" |
CRMJ | WINDING POWER RATING | 48.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 113.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 195.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 15.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 15.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY" |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS" |
TTQY | TERMINAL TYPE AND QUANTITY | 22 WIRE LEAD" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.927 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.947 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABMK | OVERALL WIDTH | 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM" |
ABTD | MOUNTING SLOT WIDTH | 0.100 INCHES MINIMUM SINGLE GROUP AND 0.160 INCHES MAXIMUM SINGLE GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA" |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 446.5 VOLT-AMPERE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.970 INCHES MINIMUM AND 3.030 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 1.280 INCHES MINIMUM AND 1.340 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | OPEN" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND SLOT SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 1.8 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 900.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CRMJ | WINDING POWER RATING | 238.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY" |
CRMJ | WINDING POWER RATING | 24.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY" |
CRMJ | WINDING POWER RATING | 45.4 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY" |
CRMJ | WINDING POWER RATING | 48.3 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 113.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 195.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 15.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 15.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 23.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY" |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; SIX SECONDARY WINDINGS" |
TTQY | TERMINAL TYPE AND QUANTITY | 22 WIRE LEAD" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote