Mfg Part Number: 254619146-272 | Alternate P/N: 254619146272 | NSN : 5950-00-444-3629 |
NIIN : 004443629 | CAGE Code : 19193 | Manufacturer: Coil Specialty Co Inc |
Item Name : Transformer Power | FSC : 5950 Coils and Transformers |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 5950-00-444-3629 parts and components with Transformer Power manufactured by MFG Coil Specialty Co Inc. Some of the items we carry include part number 254619146-272, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 5950-00-444-3629 products 254619146-272 that we feature by Coil Specialty Co Inc are paired alongside their corresponding CAGE Code 19193 and FSC 5950 Coils and Transformers More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-444-3629 Item Description: Transformer Power | 5950 | 004443629 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
254619146-272 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED" |
ABTB | MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL SINGLE GROUP0.125 INCHES NOMINAL SINGLE GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 1.690 INCHES MAXIMUM1.690 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 0.950 INCHES MAXIMUM0.950 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 0.880 INCHES MAXIMUM0.880 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS130.0 DEG CELSIUS" |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP2 SINGLE GROUP" |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 7.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED" |
ABTB | MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL SINGLE GROUP0.125 INCHES NOMINAL SINGLE GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 1.690 INCHES MAXIMUM1.690 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 0.950 INCHES MAXIMUM0.950 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 0.880 INCHES MAXIMUM0.880 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS130.0 DEG CELSIUS" |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP1.380 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP2 SINGLE GROUP" |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 7.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD" |