Mfg Part Number: W8631 | NSN : 5950-00-326-1814 | NIIN : 003261814 |
CAGE Code : 08715 | Manufacturer: Cen Electronics A Div Of Chlorid | Item Name : Transformer Power |
FSC : 5950 Coils and Transformers |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 5950-00-326-1814 parts and components with Transformer Power manufactured by MFG Cen Electronics A Div Of Chlorid. Some of the items we carry include part number W8631, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 5950-00-326-1814 products W8631 that we feature by Cen Electronics A Div Of Chlorid are paired alongside their corresponding CAGE Code 08715 and FSC 5950 Coils and Transformers More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-326-1814 Item Description: Transformer Power | 5950 | 003261814 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
W8631 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.109 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.734 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 1.766 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.375 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 3.812 INCHES NOMINAL" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS" |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL GROUPINGS" |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 125.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY25.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 125.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY30.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 25.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 25.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY30.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY125.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 30.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
TEST | TEST DATA DOCUMENT | 10001-2928145 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW" |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS" |
TTQY | TERMINAL TYPE AND QUANTITY | 16 WIRE HOOK" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.109 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.141 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.734 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 1.766 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.375 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 3.812 INCHES NOMINAL" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS" |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL GROUPINGS" |
CRBZ | WINDING OPERATING CURRENT | 300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 700.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 125.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY25.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 125.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY30.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 25.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 25.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY30.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY125.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 30.90 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
TEST | TEST DATA DOCUMENT | 10001-2928145 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW" |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS" |
TTQY | TERMINAL TYPE AND QUANTITY | 16 WIRE HOOK" |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote