Mfg Part Number: LPQ252-CF | Alternate P/N: LPQ252CF | NSN : 6130-01-525-3303 |
NIIN : 015253303 | CAGE Code : U8415 | Manufacturer: Astec Industries Inc Div Astec |
Item Name : Power Supply | FSC : 6130 Converters Electrical Nonrotating |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 6130-01-525-3303 parts and components with Power Supply manufactured by MFG Astec Industries Inc Div Astec. Some of the items we carry include part number LPQ252-CF, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 6130-01-525-3303 products LPQ252-CF that we feature by Astec Industries Inc Div Astec are paired alongside their corresponding CAGE Code U8415 and FSC 6130 Converters Electrical Nonrotating More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-525-3303 Item Description: POWER SUPPLY | 6130 | 015253303 | N | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LPQ252-CF | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 10.320 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 3.000 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL" |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT" |
APNX | INPUT VOLTAGE RATING | 120.0 DC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 300.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT" |
APNX | INPUT VOLTAGE RATING | 85.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT" |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC POUNDS PER HOUR WET 3RD POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC POUNDS PER HOUR WET 2ND POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC POUNDS PER HOUR DRY 4TH POWER OUTPUT AND 25.0 DC POUNDS PER HOUR WITH RETAINING CHAIN 4TH POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC POUNDS PER HOUR WET 1ST POWER OUTPUT" |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT" |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.0/+50.0 DEG CELSIUS" |
BGQR | OUTPUT WATTAGE RATING | 250.0 WATTS NOMINAL SINGLE POWER OUTPUT" |
CWGH | OUTPUT CURRENT RATING | 100.0 DC MILLIAMPERES NOMINAL SINGLE POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 120.0 MILLIVOLTS PEAK 2ND POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 120.0 MILLIVOLTS PEAK 3RD POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 240.0 MILLIVOLTS PEAK 4TH POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 50.0 MILLIVOLTS PEAK 1ST POWER OUTPUT" |
CWHM | INPUT CURRENT RATING | 20.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT" |
CWKG | VENTILATION DESIGN TYPE | SINGLE FAN" |
ABHP | OVERALL LENGTH | 10.320 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 3.000 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL" |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT" |
APNX | INPUT VOLTAGE RATING | 120.0 DC VOLTS MINIMUM 2ND OPERATING POWER RQMT AND 300.0 DC VOLTS MAXIMUM 2ND OPERATING POWER RQMT" |
APNX | INPUT VOLTAGE RATING | 85.0 AC VOLTS MINIMUM 1ST OPERATING POWER RQMT AND 264.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT" |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC POUNDS PER HOUR WET 3RD POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC POUNDS PER HOUR WET 2ND POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC POUNDS PER HOUR DRY 4TH POWER OUTPUT AND 25.0 DC POUNDS PER HOUR WITH RETAINING CHAIN 4TH POWER OUTPUT" |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC POUNDS PER HOUR WET 1ST POWER OUTPUT" |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT" |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.0/+50.0 DEG CELSIUS" |
BGQR | OUTPUT WATTAGE RATING | 250.0 WATTS NOMINAL SINGLE POWER OUTPUT" |
CWGH | OUTPUT CURRENT RATING | 100.0 DC MILLIAMPERES NOMINAL SINGLE POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 120.0 MILLIVOLTS PEAK 2ND POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 120.0 MILLIVOLTS PEAK 3RD POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 240.0 MILLIVOLTS PEAK 4TH POWER OUTPUT" |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 50.0 MILLIVOLTS PEAK 1ST POWER OUTPUT" |
CWHM | INPUT CURRENT RATING | 20.0 AC AMPERES NOMINAL SINGLE OPERATING POWER RQMT" |
CWKG | VENTILATION DESIGN TYPE | SINGLE FAN" |