Mfg Part Number: 222-10N12222054 | Alternate P/N: 22210N12222054 | NSN : 5930-00-402-7705 |
NIIN : 004027705 | CAGE Code : 96452 | Manufacturer: American Standard Inc |
Item Name : Switch Thermostatic | FSC : 5930 Switches |
Thank you for choosing to rely on Nascent Aviation for all your operational needs. You have reached our NSN RFQ Page where you can request quotes for our most in-demand NSN 5930-00-402-7705 parts and components with Switch Thermostatic manufactured by MFG American Standard Inc. Some of the items we carry include part number 222-10N12222054, and various others, those of which have been thoroughly assessed for quality and reliability. At Nascent Aviation, we set ourselves apart from other distributors in our steadfast commitment to providing guidance at every stage of the procurement process, offering rapid lead times, cost savings, and exceptional customer service
Nascent Aviation is commended for making quality the cornerstone of its operations, ensuring that our customers never have to worry about the authenticity of our products. The NSN 5930-00-402-7705 products 222-10N12222054 that we feature by American Standard Inc are paired alongside their corresponding CAGE Code 96452 and FSC 5930 Switches More than that, the NSN items we carry are subject to a series of rigorous quality assurance measures, tests, verifications, and assessments, as applicable. If you find a product that suits your operations, we invite you to fill out and submit an RFQ form for your comparisons. Alternatively, you can call or email us directly; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-402-7705 Item Description: Switch Thermostatic | 5930 | 004027705 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
222-10n12222054 | 2 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT" |
ABHP | III OVERALL LENGTH | 5.188 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 5.687 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL" |
AEVU | BULB LENGTH | 3.625 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL" |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AWTN | OPERATING TEMP RATING | 167.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE" |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +70.00/+140.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER" |
PRMT | PRECIOUS MATERIAL | SILVER" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT" |
ABHP | III OVERALL LENGTH | 5.188 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 5.687 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL" |
AEVU | BULB LENGTH | 3.625 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.688 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL" |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AWTN | OPERATING TEMP RATING | 167.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE" |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | +70.00/+140.00 ACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER" |
PRMT | PRECIOUS MATERIAL | SILVER" |
STYL | III STYLE DESIGNATOR | RECTANGULAR" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote